Addressable type fire alarm controller
ADDRESSABLE TYPE FIRE ALARM CONTROLLER
Model: JBS-MA
Addressable type fire alarm controller is the central unit of the fire detection and alarm system.
There are two different types of fire detection and alarm systems, conventional type and addressable type. So we have two different types fire alarm controllers, conventional type and addressable type.
This type also called non addressable type. The detectors and manual call points are arranged in Zones to simplify location the cause of the alarm. For instance, if you have a conventional type system and the alarm goes off, it would tell you the alarm zone. Each zone is indicated at the fire alarm controller both with a text display and an indicator. It is better suited for smaller ships.
Each device comes with a separate and distinct address, which allows the controller to know their status, such as in alarm, in trouble or whether it’s functioning normally. When alarm, the controller will display the alarm specific location and the user can assess the situation much more quickly. It is used for bigger ships.
The fire alarm system is consisted of fire alarm controller, smoke detectors, heat detectors, manual call points, etc.
No. | Description | IP Class |
1 | Fire alarm controller | IP44/IP20 |
2 | Fire alarm repeater | IP44/IP20 |
3 | Heat detector | IP44/IP56 |
4 | Ex. Heat detector | IP56 |
5 | Smoke detector | IP44/IP56 |
6 | Ex.smoke detector | IP56 |
7 | Manual call point | IP44/IP56 |
8 | Alarm sounder | IP44 |
Click the following for detail products information
More…
ADDRESSABLE TYPE FIRE ALARM CONTROLLER
Model: JBS-MA
Addressable type fire alarm controller is the central unit of the fire detection and alarm system.
ADDRESSABLE TYPE FIRE ALARM CONTROLLER
Model: JBS-MA
Installation method: Flush type
Addressable type fire alarm controller is the central unit of the fire detection and alarm system.
CONVENTIONAL TYPE FIRE ALARM CONTROLLER
Model: JBS-FA
Conventional type fire alarm controller is the central unit of the fire detection and alarm system. It can up to 12 zones for different ships.
CONVENTIONAL TYPE FIRE ALARM CONTROLLER
Model: JBS-FA
Installation method: Flush type
Conventional type fire alarm controller is the central unit of the fire detection and alarm system. It can up to 12 zones for different ships.
EXPLOSION PROOF MANUAL CALL POINT
Model:J-SAB-M-M500KEIS
It is designed for use in hazardous environments for manual initiation of fire alarm together with compatible fire alarm controller.
EXPLOSION PROOF MANUAL CALL POINT
Model:J-SAB-M-M500KEIS
It is designed for use in hazardous environments for manual initiation of fire alarm together with compatible fire alarm controller.
EXPLOSION-PROOF HEAT DETECTOR
Model:JTWB-BCD-5151EIS
It is used with compatible fire alarm controller for monitoring the initial fire alarm status of hazardous environmental condition.
Certification: CCS, CCC, Ex certificate
EXPLOSION-PROOF SMOKE DETECTOR
Model:JTY-GD-2151EIS
It is used with compatible fire alarm controller for monitoring the initial fire alarm status of hazardous environmental condition.
Certification: CCS, CCC, Ex certificate
FIRE ALARM REPEATER
Model: FS-100C
Installation method: wall type
Fire Alarm Repeater is designed to display the fire alarm status of fire alarm controller installed in a different location, e.g. ECR.
FIRE ALARM REPEATER
Model: FS-100C
Installation method: flush type
Fire Alarm Repeater is designed to display the fire alarm status of fire alarm controller installed in a different location, e.g. ECR.
HEAT DETECTOR
Model:JTW-BD-885
It is used with compatible fire alarm controller for monitoring the initial fire alarm status of environmental condition.
Certification: CCS, CCC
HEAT DETECTOR 90℃
Model:JTW-BD-ZR875H/T
It is used with compatible fire alarm controller for monitoring the initial fire alarm status of high temperature environmental condition, e.g. mess room.
Certification: CCS, CCC